CRC INDUSTRIES INC -- CONTACT CLEANER 2000, 02140 -- 7930-00N047770
===================== Product Identification ===================== Product ID:CONTACT CLEANER 2000, 02140 MSDS Date:06/15/1994 FSC:7930 NIIN:00N047770 === Responsible Party === Company Name:CRC INDUSTRIES INC Address:885 LOUIS DR City:WARMINISTER State:PA ZIP:18974 Country:US Info Phone Num:215-674-4300 Emergency Phone Num:215-674-4300 Preparer's Name:ADAM SELISKER CAGE:CRCIN === Contractor Identification === Company Name:CRC INDUSTRIES INC Address:885 LOUIS DR City:WARMINSTER State:PA ZIP:18974 Country:US Phone:215-674-4300 CAGE:CRCIN Company Name:CRC INDUSTRIES, INC. Address:885 LOUIS DRIVE Box:City:WARMINSTER State:PA ZIP:18974-2820 Country:US Phone:215-674-4300/800-424-9300 CAGE:10136 ============= Composition/Information on Ingredients ============= Ingred Name:ETHANE, 1,1-DICHLORO-1-FLUORO-; (1,1-DICHLORO-1-FLUOROETHANE) (SARA 313) CAS:1717-00-6 RTECS #:KI0997000 Fraction by Wt: 95-98% Other REC Limits:500 PPM (MFR) OSHA PEL:N/K ACGIH TLV:N/K Ozone Depleting Chemical:2 Ingred Name:CARBON DIOXIDE CAS:124-38-9 RTECS #:FF6400000 Fraction by Wt: 3-6% OSHA PEL:5000 PPM ACGIH TLV:5000 PPM/30000 STEL ===================== Hazards Identification ===================== LD50 LC50 Mixture:NONE SPECIFIED BY MANUFACTURER. Routes of Entry: Inhalation:YES Skin:YES Ingestion:NO Reports of Carcinogenicity:NTP:NO IARC:NO OSHA:NO Health Hazards Acute and Chronic:CHLOROFLUOROCARBON (CFC) MATERIALS HAVE PRODUCED SENSITIZATION OF MYOCARDIUM TO EPINEPHRINE IN LABORATORY ANIMALS AND COULD HAVE A SIMILAR EFFECT IN HUMANS. ADRENOMIMETICS (I.E., EPINEPHRINE) MAY BE C ONTRA-INDICATED EXCEPT FOR LIFE-SUSTAINING USES IN HUMANS ACUTELY/CHRONICALLY EXPOSED TO CFCS . (EFTS OF OVEREXP) Explanation of Carcinogenicity:NOT RELEVANT. Effects of Overexposure:HLTH HAZ:ACUTE:INHALATION:DIZZINESS, LIGHTHEADEDNESS. HIGH LEVELS MAY CAUSE ASPHYXIATION OR CARDIAC ARRHYTHMIAS. SKIN:MAY CAUSE DEFATTING, IRRITATION. EYES:MAY CAUSE IRRITATION. CHRONIC:SKIN IRRITATIO N ON REPEATED CONTACT. Medical Cond Aggravated by Exposure:IMPAIRED CARDIOVASCULAR FUNCTION SUCH AS CARDIAC ARRHYTHMIAS MAY BE SENSITIZED BY INHALATION. ======================= First Aid Measures ======================= First Aid:(IF SYMPTOMS PERSIST, CALL A PHYSICIAN). INHAL:REMOVE TO FRESH AIR. APPLY ARTIFICIAL RESPIRATION IF NECESSARY. EYES:FLUSH WITH LARGE AMOUNTS OF WATER FOR @ LEAST 15 MINUTES. SKIN:WASH AREA THOROUGHLY WITH SOAP AND WATER. INGEST:DO NOT INDUCE VOMITING. GIVE WATER TO DRINK. GET MEDICAL ATTENTION. ===================== Fire Fighting Measures ===================== Flash Point Method:TCC Flash Point:NONE Lower Limits:7.6% Upper Limits:17.7% Extinguishing Media:WATER FOG, CO*2, DRY CHEMICAL. Fire Fighting Procedures:WEAR NIOSH/MSHA APPROVED PRESSURE DEMAND SCBA & FULL PROTECTIVE EQUIPMENT . Unusual Fire/Explosion Hazard:THERMAL DECOMPOSITION PRODUCTS MAY INCLUDE FLUORIDES, CHLORIDES, AND PHOSGENE . AEROSOLS MAY EXPLODE WHEN HEATED ABOVE 120F. ================== Accidental Release Measures ================== Spill Release Procedures:EVACUATE PERSONNEL. VENTILATE AREA. ABSORB SPILL WITH AN ABSORBENT MATERIAL. Neutralizing Agent:NONE SPECIFIED BY MANUFACTURER. ====================== Handling and Storage ====================== Handling and Storage Precautions:AEROSOL CAN MAY EXPLODE IF HEATED ABOVE 120F. VAPS ARE VERY HEAVY & WILL COLLECT IN LOW AREAS. OXYG WOULD BE DISPLACED & ASPHY COULD RESULT. (SUPDAT) Other Precautions:NO SMOKING IN AREA OF USE. DO NOT USE IN GENERAL VICINITY OF ARC WELDING, OPEN FLAMES OR HOT SURFACES. HEAT AND/OR UV RADIATION MAY CAUSE THE FORMATION OF CHLORIDES, FLUORIDES OR PHOSGENE . ============= Exposure Controls/Personal Protection ============= Respiratory Protection:ABOVE TLV USE NIOSH/MSHA APPROVED SELF-CONTAINED BREATHING APPARATUS. Ventilation:USE MECHANICAL MEANS IF NECESSARY TO MAINTAIN VAPOR CONC BELOW THE TLV. Protective Gloves:SOLVENT RESISTANT. Eye Protection:ANSI APPROVED CHEM WORKERS GOGGLES Other Protective Equipment:ANSI APPRVD EMERGENCY EYE WASH & DELUGE SHOWER . Work Hygienic Practices:NONE SPECIFIED BY MANUFACTURER. Supplemental Safety and Health HNDLG/STOR:GOOD VENT IS A MUST FOR LOW/CONFINED AREAS. 1,1-DICHLORO-1-FLUOROETHANE IS SUBJECT TO SNUR RULES OUTLINED IN 40 CFR 721.1007. TSCA EXPORT NOTIFICATION REQD. ================== Physical/Chemical Properties ================== Boiling Pt:B.P. Text:89.6F,32.0C Vapor Pres:10 @ 70F Vapor Density:4.1 Spec Gravity:1.24 @ 70F Evaporation Rate & Reference:FAST Solubility in Water:SLIGHT IN WATER Appearance and Odor:CLEAR COLORLESS LIQUID WITH A FAINT ETHEREAL ODOR. Percent Volatiles by Volume:100 ================= Stability and Reactivity Data ================= Stability Indicator/Materials to Avoid:YES POWDERED METALS SUCH AS ALUMINUM, MAGNESIUM, CALCIUM, ZINC. DO NOT STORE IN ALUMINUM CONTAINERS. Stability Condition to Avoid:NONE SPECIFIED BY MANUFACTURER. Hazardous Decomposition Products:CHLORIDES, FLUORIDES . HALOGENS, HALOGEN ACIDS, POSSIBLY PHOSGENE. ==================== Disposal Considerations ==================== Waste Disposal Methods:ALL USED AND UNUSED PRODUCT SHOULD BE DISPOSED OF IN CONFORMANCE WITH LOCAL, STATE AND FEDERAL REGULATIONS. Disclaimer (provided with this information by the compiling agencies): This information is formulated for use by elements of the Department of Defense. The United States of America in no manner whatsoever, expressly or implied, warrants this information to be accurate and disclaims all liability for its use. Any person utilizing this document should seek competent professional advice to verify and assume responsibility for the suitability of this information to their particular situation.